Published 5 November 2026  ·  24 reports  ·  How to read a COA →
Analytical evidence

Twenty-four certificates of analysis, reproduced without edits

Almost every peptide supplier advertises “third-party tested”. Very few publish the report itself — with the laboratory named, the identifiers visible, and the values that did not match the label left exactly as the laboratory wrote them. These twenty-four are published in full: three we paid for, and twenty-one that arrived with the goods.

Read the client field first — these reports have two different clients. Intake A (Freedom Diagnostics): client ITide Labs, our affiliated procurement entity — we bought the material and commissioned the tests ourselves. Intake B (Vanguard Laboratory): client Aevitas Research, the brand under which material was supplied to us — these reports arrived with the goods and we did not commission them. Weigh Intake B as supplier-commissioned verification, not our own sampling. That distinction is the whole point of this page.

The two laboratories

Intake A · our sampling

Freedom Diagnostics Testing

Three consecutive accession numbers from a single intake, logged 20 October 2026. Consecutive, not curated — whatever the laboratory found, we publish.

Client: ITide Labs (affiliated procurement entity)
Methods: HPLC-UV purity, LC-MS identity, net content
Accreditation: None stated on report
Contact: Admin@www.pepcorex.com · www.pepcorex.com
Intake B · A2LA ISO 17025:2017

Vanguard Laboratory

Twenty-one reports issued to Aevitas Research between January and March 2026, supplied with the material. Every purity value carries a stated measurement uncertainty (±0.18%).

Location: Olympia, WA, USA
Accreditation: A2LA certificate #6377.01.01
Contact: testing@www.pepcorex.com · +1 360-967-7010
Methods: HPLC-UV/VIS purity and quantity, with stated uncertainty

Intake A — reports we commissioned

2610200783 · Retatrutide 30 mg
Accession 2610200783 · Search code ITid2610200783 · Lot 1
Purity 99.68% (HPLC-UV) · LC-MS identity confirmed · net content 28.23 mg against 30 mg label · reported 22 Oct 2026.
Open PDF ↗
2610200785 · Wolverine 20 mg (BPC-157 / TB-4)
Accession 2610200785 · Lot 100
Purity 99.29% · BPC-157 8.58 mg + TB-4 8.47 mg quantified separately · reported 22 Oct 2026.
Open PDF ↗
2610200786 · PT-141 10 mg
Accession 2610200786 · Lot 1
Purity 99.99% · net content 9.02 mg · LC-MS confirmed · reported 22 Oct 2026.
Open PDF ↗
Why we publish the shortfalls. The Retatrutide label says 30 mg; the laboratory measured 28.23 mg of peptide — 94% of label. That is inside normal fill and residual-moisture tolerance for a lyophilised vial, and it is only visible because the report states net content separately from purity. A COA that quotes “99.68%” and nothing else tells you nothing about how much peptide is actually in the vial.

Intake B — supplier-commissioned reports (21)

All values transcribed from the reports as issued. Reports are published as images reproduced without edits.

Sample as labelledPurity (HPLC-UV/VIS)Net contentLab ID / lotReport
BPC-157 5 mg>99.80% ±0.18%5.20 mgV260204-5 012Image ↗
BPC-157 10 mg>99.80% ±0.18%9.96 mgV260220-14 006Image ↗
BPC-157 / TB-500 · 5 + 5 mg>99.80% ±0.18%4.82 + 5.00 mgV260204-5 013Image ↗
TB-500 10 mg>99.80% ±0.18%11.48 mgV260204-5 011Image ↗
KLOW 80 mg (4-component)>99.50% ±0.18%see KLOW card belowV251224-I 003Image ↗
GHK-Cu 50 mg>99.80% ±0.18%49.86 mgV260204-5 008Image ↗
AHK-Cu 100 mg>99.80% ±0.18%99.81 mgV260204-5 009Image ↗
Ipamorelin 10 mg>99.80% ±0.18%9.00 mgV260204-5 014Image ↗
CJC-1295 (no DAC) / Ipamorelin 5+599.32% ±0.18%5.70 + 5.55 mgV260119-15 006Image ↗
Tesamorelin 10 mg99.37% ±0.18%10.45 mgV251224-I 001Image ↗
Thymosin Alpha-1 5 mg99.18% ±0.18%7.80 mgV260220-14 007Image ↗
MOTS-C 10 mg99.02% ±0.18%9.97 mgV260119-15 001Image ↗
SS-31 10 mg99.80% ±0.18%11.10 mgV260119-15 005Image ↗
AOD-9604 5 mg99.74% ±0.18%4.84 mgV260119-15 002Image ↗
Retatrutide 5 mg99.58% ±0.18%5.12 mgV251224-I 004Image ↗
Retatrutide 10 mg99.44% ±0.18%10.27 mgV260204-5 003Image ↗
Retatrutide 15 mg>99.80% ±0.18%15.65 mgV260220-14 003Image ↗
Semax 10 mg>99.80% ±0.18%9.93 mgV260220-14 002Image ↗
Selank 10 mg>99.80% ±0.18%9.91 mgV260204-5 007Image ↗
NAD+ 500 mgNAD+ 99.22% ±0.18% · nicotinamide 0.78%466 mgV260119-15 007Image ↗
PT-141 10 mg99.05% ±0.18%10.69 mgV260119-15 003Image ↗

Four reports, in detail

KLOW 80 mg — four components

V251224-I 003 · Lot 251212-BZT-KL80-01 · Reported 1/7/2026. Four separate UV traces resolved and quantified in one chromatogram: GHK-Cu 52.79 mg · TB-500 9.98 mg · BPC-157 11.51 mg · KPV 11.25 mg. Signatories: Dustin Newman (Laboratory Director), Tori Johnson (Operations Manager).

Open report image ↗

GHK-Cu 50 mg — the dermal line's anchor

V260204-5 008 · Lot 260121-BZT-CU50-01-P · Reported 2/13/2026. Purity >99.80% ±0.18%; quantity 49.86 mg against a 50 mg label — a 0.3% shortfall, tighter than the fills in Intake A.

Open report image ↗

NAD+ 500 mg — purity reported three ways

V260119-15 007 · Reported 2/3/2026. Total >99.80% ±0.18%; NAD+ 99.22% ±0.18%; nicotinamide 0.78% ±0.18%. The degradation product is named, not hidden. NAD+ quantity 466 mg against a 500 mg label.

Open report image ↗

BPC-157 / TB-500 · 5 + 5 mg

V260204-5 013 · Reported 2/13/2026. Purity >99.80% ±0.18%; BPC-157 4.82 mg and TB-500 5.00 mg — two components, two quantities, one chromatogram.

Open report image ↗

What these twenty-four reports prove

✓ Established by these documents

  • Samples tested by named, contactable US laboratories — one A2LA-accredited to ISO/IEC 17025:2017
  • Identity and purity measured instrumentally, chromatograms attached to every report
  • Net peptide content measured separately from purity
  • For Intake B: uncertainty stated and the lab's own limitation printed

⚠ Not established

  • Intake B was supplier-commissioned; the lab states it cannot confirm sample authenticity or representativeness
  • Non-UV-active impurities: residual solvents, TFA, inorganic salts, elemental impurities
  • Sterility, endotoxin or microbial limits — none appear on any report
  • Future lots — always request the COA of the lot quoted to you
  • Regulatory status — nothing here approves human, veterinary, food or cosmetic use

Verify a report yourself

Do not take our transcription as evidence. Both laboratories can be contacted directly:

  1. Freedom Diagnostics Testing — Admin@www.pepcorex.com / FreedomDiagnosticsTesting.com. Quote the accession number (e.g. 2610200783) and search code (ITid2610200783).
  2. Vanguard Laboratory — testing@www.pepcorex.com / www.pepcorex.com / +1 360-967-7010. Quote the Laboratory ID (e.g. V251224-I 003) and lot number. Accreditation: A2LA certificate #6377.01.01, searchable in the public A2LA directory.
  3. Ask each laboratory to confirm the client, sample description, values and report date for those identifiers.
Published 5 November 2026. All report values transcribed from documents as issued. Links point to the original published files on pepcore-bio.com. Research use only.
💬